Compare 20–60mJ Laser Rangefinder & Designator Modules

Compare pulse energy, specified ranging distance, and beam divergence across ERDI's 1064nm rangefinder-designator modules to support initial model selection.

Model

Pulse Energy

Ranging Distance

Beam Divergence

LDR20K1

≥20mJ

≥3km

≤0.6mrad

LDR25K1

≥25mJ

≥5km

≤0.5mrad

LDR40K1

≥40mJ

≥6km

≤0.4mrad

LDR40K3

≥40mJ

≥5km

≤0.5mrad

LDR60K1

≥60mJ

≥10km

≤0.3mrad

Ranging distances are specified under model-dependent target and environmental conditions. Actual performance depends on target characteristics, atmospheric visibility, and system configuration. Refer to individual product datasheets for detailed ranging and designation specifications.

Compare pulse energy, specified ranging distance, and beam divergence across ERDI's 1064nm rangefinder-designator modules to support initial model selection.

Model

Pulse Energy

Ranging Distance

Beam Divergence

LDR20K1

≥20mJ

≥3km

≤0.6mrad

LDR25K1

≥25mJ

≥5km

≤0.5mrad

LDR40K1

≥40mJ

≥6km

≤0.4mrad

LDR40K3

≥40mJ

≥5km

≤0.5mrad

LDR60K1

≥60mJ

≥10km

≤0.3mrad

Ranging distances are specified under model-dependent target and environmental conditions. Actual performance depends on target characteristics, atmospheric visibility, and system configuration. Refer to individual product datasheets for detailed ranging and designation specifications.

FAQs

What is the difference between laser ranging and laser designation?

Laser ranging measures the distance to a target, while laser designation provides coded laser illumination for compatible systems. ERDI's 1064nm rangefinder-designator modules integrate both functions, with operating modes and performance specifications varying by model.

How should I compare the 20mJ, 25mJ, 40mJ, and 60mJ models?

Pulse energy is one selection factor, but it should be evaluated alongside beam divergence, specified ranging and designation performance, module dimensions, weight, and electrical requirements.

Do all 1064nm rangefinder-designator modules use the same communication interface?

No. Communication interfaces and electrical configurations vary by model. Review the individual product datasheets to confirm the required supply voltage, interface type, and control protocol.

Where can I find detailed specifications and mechanical drawings?

Each product page provides model-specific technical information and available documentation. For additional integration requirements, contact ERDI with your application details.