Erbium Laser Rangefinder Module 1535nm - 6km
MOQ
After-Sales Support
Choose ERDI modules with confidence.
OEM/ODM Capabilities
Support Global Delivery
30-day TrialTake
PRODUCT DESCRIPTON
The ERDI LASER® LRF0610C is a Class 1 eye-safe 1535nm laser rangefinder module built with a 200μJ erbium glass laser, delivering ≥6000m ranging capability for NATO targets. Designed for high-altitude border surveillance, naval stabilized platforms, and UAV optical pods, it offers stable operation from −40℃ to +70℃, supports 0.5–10Hz ranging, and ensures high accuracy with ±2m precision and ≥98% detection probability.
Key Advantages
• Ultra-long-range capability: ≥6000m detection on NATO targets with high precision and ≤1% false-alarm rate.
• Rugged military-grade reliability: Bonded-crystal laser core with MIL-STD-810G shock and vibration resistance.
• High measurement performance: ±2m accuracy, ≤0.1m resolution, and multi-target detection (up to 3 targets).
• Integration-friendly design: Compact 70×32×40mm structure, ≤90g weight, UART (TTL_3.3V) duplex communication, and low 2.5W average power consumption.
TECHNICAL PARAMETERS
| Project | Performance Indicators |
| Model | LRF0610C |
| Laser Wavelength | 1535±5nm |
| Eye- safety | Class Ⅰ |
| Divergence Angle | ≤0.5 mrad |
| Laser Energy | ≥200 μJ |
| Launch Lens Diameter | Φ10 mm |
| Receiver Lens Diameter | Φ25 mm |
| Measuring Range
(Reflectance 30%; visibility ≥ 8km.) |
NATO objective(2.3m×2.3m) ≥6000m
Measuring human target(0.5m×1.7m) ≥1500m |
| Minimum Range | ≤15 m |
| Ranging Frequency | 0.5Hz ~10Hz |
| Number of multi-target detections | Up to 3 targets |
| Ranging Accuracy | ±2 m |
| Range Resolution | ≤0.1m |
| Precision Rate | ≥98% |
| False Alarm Rate | ≤1% |
| Pin-in-lead package model | Molex51021-0500 |
| Supply Voltage | DC12 V |
| Standby power consumption | ≤1 mW |
| Average power consumption | ≤2.5 W @10 Hz |
| Peak Power Consumption | ≤7 W @12 V |
| Weight | ≤90g |
| Dimension (L×W×H) | 70mm×32mm×40mm |
| Operating Temperature | -40~+70 ℃ |
| Storage Temperature | -55~+75 ℃ |
| Impact Resistance | Meet the MIL-STD-810G testing standard |
| Vibration Resistance | Meet the MIL-STD-810G testing standard |
DIMENSION(mm)

INTERFACE
Electrical connector model: Molex51021-0500. The detailed definition of the electrical interface is as follows:
Table 1 Interface definition
| External plug-in XS3 | Model:Molex51021-0500 | Remark |
| 1 | TTL RX | 3.3V |
| 2 | TTL TX | 3.3V |
| 3 | CTRL | 3.3V-5V power on, 0V power off |
| 4 | +5V | Power supply+ |
| 5 | GND | Power supply- |
Information Download
-
PRODUCT DESCRIPTON
-
TECHNICAL PARAMETERS
-
DIMENSION(mm)
-
INTERFACE
-
Information Download
The ERDI LASER® LRF0610C is a Class 1 eye-safe 1535nm laser rangefinder module built with a 200μJ erbium glass laser, delivering ≥6000m ranging capability for NATO targets. Designed for high-altitude border surveillance, naval stabilized platforms, and UAV optical pods, it offers stable operation from −40℃ to +70℃, supports 0.5–10Hz ranging, and ensures high accuracy with ±2m precision and ≥98% detection probability.
Key Advantages
• Ultra-long-range capability: ≥6000m detection on NATO targets with high precision and ≤1% false-alarm rate.
• Rugged military-grade reliability: Bonded-crystal laser core with MIL-STD-810G shock and vibration resistance.
• High measurement performance: ±2m accuracy, ≤0.1m resolution, and multi-target detection (up to 3 targets).
• Integration-friendly design: Compact 70×32×40mm structure, ≤90g weight, UART (TTL_3.3V) duplex communication, and low 2.5W average power consumption.
| Project | Performance Indicators |
| Model | LRF0610C |
| Laser Wavelength | 1535±5nm |
| Eye- safety | Class Ⅰ |
| Divergence Angle | ≤0.5 mrad |
| Laser Energy | ≥200 μJ |
| Launch Lens Diameter | Φ10 mm |
| Receiver Lens Diameter | Φ25 mm |
| Measuring Range
(Reflectance 30%; visibility ≥ 8km.) |
NATO objective(2.3m×2.3m) ≥6000m
Measuring human target(0.5m×1.7m) ≥1500m |
| Minimum Range | ≤15 m |
| Ranging Frequency | 0.5Hz ~10Hz |
| Number of multi-target detections | Up to 3 targets |
| Ranging Accuracy | ±2 m |
| Range Resolution | ≤0.1m |
| Precision Rate | ≥98% |
| False Alarm Rate | ≤1% |
| Pin-in-lead package model | Molex51021-0500 |
| Supply Voltage | DC12 V |
| Standby power consumption | ≤1 mW |
| Average power consumption | ≤2.5 W @10 Hz |
| Peak Power Consumption | ≤7 W @12 V |
| Weight | ≤90g |
| Dimension (L×W×H) | 70mm×32mm×40mm |
| Operating Temperature | -40~+70 ℃ |
| Storage Temperature | -55~+75 ℃ |
| Impact Resistance | Meet the MIL-STD-810G testing standard |
| Vibration Resistance | Meet the MIL-STD-810G testing standard |

Electrical connector model: Molex51021-0500. The detailed definition of the electrical interface is as follows:
Table 1 Interface definition
| External plug-in XS3 | Model:Molex51021-0500 | Remark |
| 1 | TTL RX | 3.3V |
| 2 | TTL TX | 3.3V |
| 3 | CTRL | 3.3V-5V power on, 0V power off |
| 4 | +5V | Power supply+ |
| 5 | GND | Power supply- |